Commercial Electric CE1011S-06 Instruction Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
Page 6
PARTS INCLUDED FOR INSTALLATION (parts are not to scale):
INSTALLATION INSTRUCTIONS:
1. Thread the Fixture Mounting Screws (#8) onto the Outlet Box (#6), as shown. (Fig. 2)
2. Pull the power supply wires out from the Outlet Box (#6). Attach the Black Supply Wire (#14)
to the Black Fixture Wire (#15) and the White Supply Wire (#9) to the White Fixture Wire (#11)
using Wire Nuts (#10). Connect the Fixture Ground Wire (#12) and the Supply Ground Wire
(#13) together using a Wire Nut (#10). (Fig. 3) Wrap all wire connections with electrical tape for
a more secure connection. Note: If you have electrical questions, consult your local electrical
code for approved grounding methods.
3. Carefully, tuck all the wires and wire connections into the Outlet Box (#6). Place the Fixture Pan
(#1) over the Outlet Box (#6) and onto the Fixture Mounting Screws (#8), making sure they feed
through the Keyhole Slots (#16). (Fig. 4)
4. Twist the Fixture Pan (#1) clockwise, so that the Fixture Mounting Screws (#8) slide into the
narrow ends of the Keyhole Slots (#16). Tighten the Fixture Mounting Screws (#8) so that the
Fixture Pan (#1) is secured flush against the Ceiling. (Fig. 4 and 4-1)
5. Proceed to Step 3 of the Assembly Instructions.
6. Installation is complete. Turn on power at the circuit breaker or fuse box. Turn the light switch
on to activate the fixture.
1 ea Fixture Pan (#1)
2 ea Fixture Mounting
Screws (#8)
3 ea Wire Nuts (#10)
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 19 20